Fire Wire Size Calculator

Determine the correct electrical wire size for fire alarm systems, emergency lighting, and fire safety circuits. Ensure reliable power delivery during emergencies.

Select System Voltage Get Wire Size Result

System Parameters

Amps

Total current drawn by fire system devices

Distance from power source to farthest device

Copper is standard for fire safety systems

%

Maximum acceptable voltage loss (fire systems typically use 3-5%)

Wire Size Recommendation

Enter system parameters and click "Calculate Wire Size" to see recommendations

Safety Disclaimer

This calculator provides general guidance only. Always consult local electrical codes (NEC, CEC) and certified electricians for fire safety system installations.

Understanding Fire Wire Size

When it comes to fire safety systems, the wiring isn't just about getting power from point A to point B. It's about ensuring that power arrives reliably, even during the chaos of an emergency. Fire alarms, emergency lights, and control panels depend on stable electricity to save lives.

Too thin a wire and you'll get voltage drop - the power weakens as it travels down the cable. Alarms might not sound, lights might flicker, and control panels might fail. Too thick a wire and you're wasting money on overkill. The sweet spot depends on the current draw, cable length, and how much voltage loss you're willing to accept.

Fire safety systems typically allow for more voltage drop than regular circuits (up to 5% instead of 3%), but the consequences of failure are much higher. This calculator helps you find that critical balance.

What Happens If Wire Size Is Wrong

Picture this: You've installed a beautiful fire alarm system throughout your building. Everything looks professional, the inspector gave it a thumbs up, and everyone feels safe. Then one night, a small fire starts in the storage room. The alarm should blare, lights should illuminate escape routes, and the fire department should be notified automatically.

But if your wires are too thin, the voltage drop might be just enough to prevent the alarm from sounding at full volume. Or maybe the emergency lights flicker instead of staying bright. In a real emergency, those precious seconds matter. People might not wake up, might not see the exit signs clearly, or the automatic notification to emergency services might fail.

On the other hand, using wire that's way too thick doesn't hurt anything except your wallet. But it's better to be safe than sorry when lives are on the line.

How the Calculator Works

The calculator takes your system parameters and runs them through electrical engineering formulas to determine the minimum wire size needed. It considers the current your system draws, how far that current needs to travel, and how much voltage loss you're willing to accept.

For fire safety systems, we use more conservative calculations than regular household wiring. The allowed voltage drop is typically 3-5% (compared to 3% for general lighting circuits). This ensures reliable operation even under stress.

The calculator supports both copper and aluminum wire, though copper is strongly recommended for fire safety systems due to its superior conductivity and reliability.

Results are provided in both AWG (American Wire Gauge) and metric measurements to accommodate different regional standards.

Fire Wire Size Formula

Voltage Drop Formula

Wire Size (Circular Mils) = (2 × Length × Current × 1000) ÷ (Voltage Drop × Conductivity)

Where:

  • Length = One-way cable distance (feet)
  • Current = Load current in amps
  • Voltage Drop = Allowed voltage loss percentage
  • Conductivity = Wire material constant (copper = 100% IACS, aluminum = 61% IACS)

Why Distance Matters

The longer your cable run, the thicker the wire needs to be. Electricity encounters resistance as it travels through wire, and that resistance increases with distance. What might work fine for a 20-foot run could fail completely at 100 feet with the same wire size.

Example: 24V Fire Alarm Circuit

Wire Size Recommendations

Current (A) Cable Length (m) Wire Size (AWG) Wire Size (mm²)
1.5 30 18 AWG 0.75 mm²
2.5 50 16 AWG 1.5 mm²
4.0 70 14 AWG 2.5 mm²
6.0 100 12 AWG 4.0 mm²

Understanding the Pattern

Notice how both higher current and longer distances require thicker wire. A system drawing 4 amps over 70 meters needs 14 AWG wire, while the same current over just 30 meters could use thinner 16 AWG. Fire safety systems prioritize reliability over cost.

When to Use This Calculator

  • Home Fire Systems: Planning residential smoke detector wiring or emergency lighting circuits.
  • Commercial Buildings: Office fire alarm systems, sprinkler controls, and emergency exit lighting.
  • Healthcare Facilities: Hospital alarm systems and critical emergency power circuits.
  • Educational Buildings: School fire alarm systems and classroom emergency lighting.
  • System Upgrades: When adding devices to existing fire systems or extending cable runs.

Final Thoughts

Fire safety systems are the last line of defense when things go wrong. The wiring might not be glamorous, but it's absolutely critical. Use this calculator to ensure your fire safety systems have the electrical backbone they need to perform when lives depend on them.